Ultrasensitive Two-Wire Field-Programmable
Chopper-Stabilized Unipolar Hall Effect Switches
A1185 and
A1186
11
Allegro MicroSystems, Inc.
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
V
PH
V+
t
V
PM
V
PL
0
Encode 00100
2
 (4
10
)
Enable
Address
Address
Blow
Blow
Enable
Encode 00001
2
 (1
10
)
Figure 6. Pulse sequence to permanently encode calibration value 5 (101 binary, or
bitfield address 3 and bitfield address 1).
V
PH
V+
t
V
PM
V
PL
0
Try 5
10
Enable
Address
Clear
Optional
Monitoring
The pulse sequences consist of the following groups of pulses:
1. An enable sequence.
2. A bitfield address sequence.
3. When permanently setting the bitfield, a long V
PH
 fuse-blow-
ing pulse. (Note: Blown bit fuses cannot be reset.)
4. When permanently setting the bitfield, the level of V
CC
 must
be allowed to drop to zero between each pulse sequence, in
order to clear all registers. However, when provisionally set-
ting bitfields, V
CC
 must be maintained at V
PL
 between pulse
sequences, in order to maintain the prior bitfield settings while
preparing to set additional bitfields.
Bitfields that are not set are evaluated as zeros. The bitfield-level
fuses for 0 value bitfields are never blown. This prevents inad-
vertently setting the bitfield to 1. Instead, blowing the device-
level fuse protects the 0 bitfields from being accidentally set in
the future.
When provisionally trying the calibration value, one pulse
sequence is used, using decimal values. The sequence for setting
the value 5
10
 is shown in figure 5.
When permanently setting values, the bitfields must be set indi-
vidually, and 5
10
 must be programmed as binary 101. Bit 3 is
set to 1 (000100
2
, which is 4
10
), then bit 1 is set to 1 (000001
2
,
which is 1
10
). Bit 2 is ignored, and so remains 0.Two pulse
sequences for permanently setting the calibration value 5 are
shown in figure 6. The final V
PH
 pulse is maintained for a longer
period, enough to blow the corresponding bitfield-level fuse.
Figure 5. Pulse sequence to provisionally try calibration value 5.
相关PDF资料
A1193LUA-T IC SW HALL EFFECT CHOPPER 3SIP
A1203LUA-T IC SW CONTINUOUS TIME BIPO 3-SIP
A1205EUA-T IC SWITCH HALL EFFECT GP 3-SIP
A1211LUA-T IC LATCH HALL EFFECT 3-SIP
A1220LUA-T IC HALL EFFECT LATCH 3V 3-SIP
A1242LUA-I2-T IC LATCH HALL EFFECT 3-SIP
A1244LUA-I2-T IC HALL EFFECT LATCH SIP-3
A1302KUA-T IC SENSOR HALL EFFECT 3-SIP
相关代理商/技术参数
A1187 制造商:Quick 功能描述:TSOJ 18.5mm x 8mm Nozzle for 21-13205 and 21-13210 制造商:QUICK 功能描述:TSOJ 18.5 X 8 NOZZLE FOR QUICK957/957D
A1-18-701-15 制造商:Southco 功能描述:
A118734 制造商:SRC Devices 功能描述: 制造商:Coto Technology 功能描述:
A1188 制造商:Quick 功能描述:PLCC 9 X 9 NOZZLE FOR QUICK957/957D
A1189 制造商:Quick 功能描述:PLCC 34mm X 34mm Nozzle for 21-13205 and 21-13210 制造商:QUICK 功能描述:PLCC 34 X 34 NOZZLE FOR QUICK957/957D 制造商:HAKKO Corporation 功能描述:
A-1189 制造商:TE Connectivity 功能描述:
A118-9 制造商:APEM 功能描述:
A1189B 制造商:HAKKO Corporation 功能描述: